High-voltage contactor up to 4,800 V
Single-pole NO contactor CH1130 AC and DC (semi-bidirectional). Rated insulation voltage 4,800 V; conventional thermal current 250 A.
CH1130
The AC and DC contactor CH1130 is an update of the CH range tried and tested over many decades, the four series of which it supersedes. The design was completely revised based on the CT range. Accordingly, permanent magnets and ceramic elements are also used for arc quenching in the CH1130; but without the electromagnets of the CT series, the CH is significantly more compact.
With the CH1130, the user possesses an economic and high-grade alternative to the 3 kV contactor (rated insulation voltage 4,800 V). The contactor is used as a pre-charging contactor in power supply systems, as well as a main contactor in heating and air-conditioning systems.
Features
The CH contactor was redesigned based on the CT technology. Since the CH does not require any electromagnetic blowout, the substructure can be omitted.
The CH has two electric arc extinguishing areas. The top area supports the main direction of the current – with full switch-off capacity. The bottom area is used for the reverse direction – with reduced switching capacity.
One part of the top arcing chamber can be removed to inspect the wear condition of the contact pills.
The contactor is especially well-suited as a pre-charging contactor in power supply systems, as well as a main contactor of heat registers in heating and air-conditioning systems. The CH complies with the following railway standards:
- EN 60077-1 and EN 60077-2
- EN 61373
Based on its approval for rail applications (EN 60077-1, EN 60077-2), the contactor also works in extreme temperatures. For temperatures under –40°C, the snap-action switch S926 is used as an auxiliary contact.
Specifications
Type of voltage | DC (semi bidirectional), AC (f < 60 Hz) |
Main contacts, configuration | 1x SPST-NO |
Nominal voltage Un | 3,000 V |
Rated operating voltage Ue | 3,600 V |
Rated insulation voltage UNm | 4,800 V |
Rated impulse withstand voltage UNi | 25 kV |
Conv. thermal current Ith | 250 A |
Pollution degree Overvoltage category |
PD3 / OV3 |
Aux. contact | 2x S826, silver, DC13/110 V: 0.2 A, 24 V: 2 A |
Coil voltage Us | 24 / 36 / 72 / 110 V DC |
Coil tolerance | –30 % … +25 % Us |
Vibration / Shock (IEC 61373) | Class B, Category 1 |
Mounting orientation | horizontal / vertical |
Temperature range | –40 °C… +70 °C |
Mechanical endurance | >2 million operating cycles |
What do you want to do?
Do you have questions about this product?
Bookmark product