S134 – Emergency disconnect switch for industrial trucks
1 pole Emergency disconnect switch (NC) with snap-action switch mechanism for battery voltages of up to 160 V DC. Conventional thermal current up to 250 Ampere.
S134
1 pole emergency disconnect switch for industrial trucks
Installation of emergency disconnect switches enhances safety at the work place significantly (meeting requirements for accident prevention). Single pole S134 switches are especially designed for DC applications.
Thanks to its snap mechanism the switch once actuated will complete the switch-off procedure in any case, because the snap mechanism works independently of the actuator. For ON and OFF there are two maintained positions.
Features
- Single pole emergency disconnect switch with snap mechanism
- Magnetic blowout
- Two definite maintained positions (ON/OFF)
- Optional lockable version
- Optional auxiliary contact
Stock items
- S134-1-Z0-H00-M8-L1
- S134-1-Z0-H00-M8-L2
- S134-1-Z0-H11-M10-L2
- S134-1-Z1-H00-M10-L1
- S134-1-Z1-H01-M10-L1
- S134-1-Z1-H31-M10-L1
- S134-1-Z2-H00-M10-L1
- S134-1-Z2-H11-M10-L1
Specifications
S134
Type of voltage | DC |
Main contacts, configuration | 1 x NC |
Nominal voltage Un | 100 V |
Rated insulation voltage Ui | 160 V |
Rated impulse withstand voltage Uimp | 4 kV bei PD3 |
Conv. thermal current Ith | 250 A |
Permissible inrush current | 1,500 A |
Rated operating current Ie | 24 V DC, L/R=15 ms: 300 A, 80 V DC, L/R=15 ms: 250 A |
Max. breaking capacity | 24 V DC, L/R=15 ms: 1,200 A, 80 V DC, L/R=15 ms: 1,000 A |
Mechanical endurance | > 30,000 operating cycles |
IP rating (IEC 60529) | IP00 |
Mounting orientation | any |
Terminals | screw-type M8, M10 |
Aux. contact | S840, S870, S826 |
What do you want to do?
Do you have questions about this product?
Bookmark product